G4 Low-voltage Mechanical Relay Output, 5 VDC logic, normally closed

 0,00

G4 Low-voltage Mechanical Relay Output, 5 VDC logic, normally closed

Out of stock

SKU: G4ODC5R5 Categories: , Brand:

Description

The G4ODC5R5 is a low-contact-resistance DC output. It is a single-pole, single-throw, normally closed mechanical relay (Form A, SPST-NC). It was designed for a low-voltage DC load that is purely resistive (no inrush current). Typical applications for these modules include analog signal and communication line multiplexing. Because of their low 10 VA rating, these modules are not recommended for inductive or capacitive loads (even very small loads) because the inrush current is likely to exceed the 10 VA rating.

Attachments

Product features

  • Model: G4
  • ETIM Code: EC001437
  • ETIM Class: Switching relay
  • Type of electric connection: PCB connection
  • Complete with socket: No
  • With detachable clamps: No
  • With LED indication: Yes
  • Rated control supply voltage DC: 4.8 - 6 Volt
  • Voltage type for actuating: DC
  • Drive, polarization: Polarized
  • Drive, switching attitude: Mono stable
  • Number of contacts as normally closed contact: 1
  • Type of switch contact: Single contact
  • With forced-guided contacts: No
  • Material contact: Beryllium copper
  • Material of contact surface: Gold
  • Voltage type (operating voltage): AC/DC
  • Operating voltage AC 50 Hz: 10 - 130 Volt
  • Operating voltage AC 60 Hz: 10 - 130 Volt
  • Operating voltage DC: 10 - 100 Volt
  • Nominal current: 0.1 Ampere
  • Max. starting current: 0.5 Ampere
  • Width: 48.8 mm
  • Height: 41.1 mm
  • Depth: 12.2 mm
  • Variant: Output modules DC

Description

The G4ODC5R5 is a low-contact-resistance DC output. It is a single-pole, single-throw, normally closed mechanical relay (Form A, SPST-NC). It was designed for a low-voltage DC load that is purely resistive (no inrush current). Typical applications for these modules include analog signal and communication line multiplexing. Because of their low 10 VA rating, these modules are not recommended for inductive or capacitive loads (even very small loads) because the inrush current is likely to exceed the 10 VA rating.

Attachments

Get a quote

Do you have any questions or need more information about a product?

Our experts are happy to help you!

Contact us+31 85 800 3700
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.